User's Manual Chapter 4 Configuring a Typical Application
LRS-24 RADview/TDM SHDSL Applications 4-9
4.2 SHDSL Applications
Figure 4-1
illustrates a typical SHDSL application, where a 4-wire ASMi-52CD card
operates opposite two standalone ASMi-52 modems.
E1
PBX
PBX
E1
E1s
ASMi-52
ASMi-52
LRS-24
ASMi-52CD
4-wire
4-wire
Central Site Remote Site
Public
Network
RADview
Management
Station
Figure 4-9. SHDSL Application
SHDSL Configuration
The recommended SHDSL configuration procedure of the local and remote units
include the following steps:
1. Performing preliminary configuration (IP parameters) of LRS-24 via ASCII
terminal (see page
4-2
)
2. Configuring ASMi-52CD and ASMi-52 via RADview:
Entering IP address of the RADview management station (see page
4-4)
Masking/unmasking remote traps (see
page
4-4)
Configuring the clock mode of ASMi-52CD (see
page
4-10
)
Configuring SHDSL line parameters (see page
4-10
)
Configuring E1 parameters (see page
4-13
).
3. Connecting the DTEs to the modems.
Comentarios a estos manuales