User's Manual Appendix B LED Indicators
LRS-24 RADview/TDM LRS-24 LED Indicators B-9
Name Color LED On LED Off
OPTICAL LOW 1 – 2 Red –
See
Testing FOMi-E1/T1 Card
Conditions
ERR 1 - 2 Red Failure occurred –
Testing FOMi-E1/T1 Card Conditions
To light LEDs for tester use (
Figure B-1
):
1. Set AIS Enable jumper to ON for the near-end master modem.
2. Disconnect the IN electrical wire in the far-end modem to turn on the LEDs:
ELECTRICAL LOW in far-end modem
OPTICAL AIS in near-end modem
3. Disconnect the IN Optic wire in the near-end master modem, starting with
initial state (jumper ON).
This will turn the OPTICAL LOW LED ON in the near-end modem.
4. Disconnect both electrical wires of the far-end modem, starting with initial
state (jumper ON).
5. Connect a ‘Loop’ between the IN-OUT electrical entries of the near-end
modem.
This will turn ON the LEDs:
ELECTRICAL LOW in far-end modem
OPTICAL AIS and ELECTRICAL AIS in near-end modem.
Front Panel
IMOD
Near-end
Master
Far-end
Slave
Optic Wires
Modem
Back Panel
Electrical Wires
Electrical Wires
Figure B-1. FOMi-E1/T1 Connection
MTMi-20C Card LED Indicators
Table B-18. MTMi-20C LEDs
Name Color LED On LED Off Blinking
POWER Green Always – –
TD Yellow – Not blinking Data passing through
RD Yellow – Not blinking Data passing through
RTS Yellow RTS status = On
DCD Yellow DCD status = On