Chapter 5 Performance Management User's Manual
5-14 Monitoring Modem Performance LRS-24 RADview/TDM
Figure 5-10. Line (HDSL) Intervals Data Table
Table 5-5. Line (HDSL) Intervals Data Parameters
Parameter Possible Values / Remarks
Time Elapsed
(sec)
Amount of time that has passed since the beginning of the current 15-minute interval
0..899
Read-only
ES Errored Seconds
A second containing one or more of the following events:
CRC error event, SEF (OOF) event, or AIS
OOF defect is the occurrence of framing bits error
If SES is also effective at the same time, ES will run for 10 seconds and stop
Read-only
SES Severely Errored Seconds
320 or more CRC error events, one or more SEF (OOF), or AIS. OOF defect is the occurrence
of framing bits error
Read-only
BBE Background Block errors. Errored blocks that do not occur in severely errored blocks.
ASMi-51/CD/CQ only
Read-only
UAS Unavailable Seconds
Number of seconds in the current interval in which a failed signal state exists
Read-only