Chapter 3 Configuration Management User's Manual
3-56 Setting Operational Parameters LRS-24 RADview/TDM
Table 3-23. TSA Color Coding
Cell Color Remarks
DTE (E1) Green At least one cell is connected
Gray Cell is available for connection
Blue Cell is not available for connection
Inside cells Gray Cell is available for connection
Yellow Cell is transferred to HDSL line
Blue Cell is not available for connection
Title Names Gray None of the cells has been selected to be transferred to
the HDSL line
Yellow Some of the cells have been selected to be transferred to
the HDSL line
Green All TSs are selected to be transferred to the HDSL line
Connecting Timeslots
To connect a timeslot:
1. In the Timeslots Assignment Table (see
Figure 3-38
), select the desired cell
and click <Connect>.
2. Click <Set>.
Disconnecting Timeslots
To disconnect a timeslot:
1. In the Timeslots Assignment Table (see
Figure 3-38
), select the desired cell
and click <Disconnect>.
2. Click <Set>.
Connecting a Group of Timeslots
You can assign a group of consecutive timeslots. This enables you to save the
time otherwise required to assign each timeslot separately.
To assign a group of timeslots
1. In the Timeslots Assignment Table, click <Group>.