Chapter 5 Performance Management User's Manual
5-4 Monitoring Modem Performance LRS-24 RADview/TDM
Figure 5-2. Polling Interval Dialog Box
7. In the BERT Polling Interval dialog box, click the drop-down arrow to select
the desired polling interval. Possible values for polling interval are 10, 30
, 60
seconds. The default value is 30
seconds.
8. Click <Set> to implement the changes.
The BERT Polling Interval dialog box closes.
9. Click <Close> to close the DTE1 Testing dialog box.
The Refresh option is not available for the following tests: ANA+BERT, REM+BERT
and BERT.
When you close the Test Dialog Box the polling interval returns to the default
value (30).
Table 5-1. DTE1 Testing Parameters
Parameters Possible Values / Remarks
Near-End Slot I/O-1 to I/O-12
Read-only
Modem Near-End or Far-End
1/2 for CD, 1/2/3/4 for CQ
Read-only
Type Modem Type
ASMi-24/C, ASMi-31/C, ASM-40/CD, ASMi-50/C, ASMi-50/CD, FOMi-E1/T1, FOMi-E1/T1/CD,
FOMi-40, FOMi-40/CD, MTMi-20C, ASMi-31CQ, ASMi-51CD, ASMi-51CQ, ASMi-52
CD/CD4w/CQ
For CDs and CQs only, modem type and number displayed (for example,
ASM-40/CD–Modem 1)
Read-only
Mode Modem mode
Master-Permanent, Master-Temporary, Slave-Permanent, Slave-Temporary
Read-only
SHDSL Mode Available for ASMi-52 family only.
STU-C, STU-R (for Modem Port Line Clock Source)
Read-only
Note