Chapter 2 Installation and Operation User's Manual
2-4 Connecting to the Management Station LRS-24 RADview/TDM
Parameter Possible Values / Remarks
Chassis IP Mode Single: Only one IP address. (The LRS-24 address is the CM-2 address.) CM-2
receives SMOD message and transfers to it to the SMOD modem after adjusting
the IP. The IP is resolved from the community field. In this mode, ping and Telnet
cannot be used directly on an SMOD; only the CM-2 IP address is relevant.
Multiple: Normal mode. Every SMOD has its own IP address and the CM-2 does
not interfere at the IP level. Every SMOD IP is calculated by adding the CM-2 IP
address and the SMOD slot number.
Serial Line Protocol SLIP.
RS-232 terminal
Station Clock Set station clock type.
Internal
External-Square
External-AMI
Terminal Rate Sets terminal rate.
9600 or 38400 bps
Default value: 38400 bps
TFTP Retry Timeout
(sec)
General retransmission time-out value.
Default value: 15 seconds
2.2 Connecting to the Management Station
To connect the RADview/TDM management station to LRS-24 units, use either of
the following setups:
• Direct management connection to LRS-24 link running on Ethernet
• Connection from management station in a LAN through an MBE to the local
standalone modem.
Direct Management Connection
In this application, the management station is connected directly to an HTU-2,
HCD-E1 or HTU-E1 unit. If more than one device is installed on this network, the
device directly connected to management is the
local
unit. Any other devices are
remote
.
This application requires installation of SLIP. It is the customer's responsibility to
acquire a SLIP communication program and to install it according to the
manufacturer's instructions. RADview/TDM supports both public domain SLIP and
vendor SLIP.
Figure 2-2
shows a sample direct management application.