User's Manual Chapter 3 Configuration Management
LRS-24 RADview/TDM Setting Operational Parameters 3-57
Figure 3-39. Group Connection Dialog Box
2. Fill in the fields, as described in
Table 3-24
.
3. Click <Set> to implement the changes.
Table 3-24. Group Connection Parameters
Parameter Possible Values / Remarks
All Connects All Timeslots
Sequence Connects Sequence of Timeslots
No. of TS Number of timeslots in the sequence
1..31
Note: Relevant only when Sequence is selected
Start TS Starting TS
1..31
Note: Relevant only when Sequence is selected
Resetting All Timeslots
To reset all timeslots:
1. In the Timeslots Assignment Table, click <Reset All>.
Figure 3-40. Remove Timeslot Connections Dialog Box
2. Click <OK> to confirm.