RAD Data comm ASMI-450 Manual de usuario Pagina 153

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 160
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 152
User's Manual Appendix B LED Indicators
LRS-24 RADview/TDM LRS-24 LED Indicators B-7
Name Color LED On LED Off Blinking
ALM red An alarm enters the buffer of local
or remote unit
ACT yellow For Ethernet, blinks according to
the Ethernet traffic activity
(10/100BaseT connector),
available only when multiplexed
Rear Panel
ACT yellow Blinks according to the Ethernet
traffic activity (10/100BaseT
connector)
LINK green Good link integrity (10/100BaseT
connector)
FOMi-40C Card LED Indicators
Table B-14. FOMi-40C LEDs
Name Color LED On LED Off Blinking
POWER Green Always
TD Yellow TD = 0 TD = 1 Data passing through
RD Yellow RD = 0 RD = 1 Data passing through
RTS Yellow RTS status = On
DCD Yellow DCD status = On
LINE LOS Red Loss of synchronization on line interface
TEST Red Test is running When not On
ERR Red Failure occurred
FOMi-40CD Card LED Indicators
Table B-15. FOMi-40CD LEDs
Name Color On Off Blinking
POWER Green Always
TD 1 – 2 Yellow TD = 0 TD = 1 Data passing through
RD 1 – 2 Yellow RD = 0 RD = 1 Data passing through
RTS 1 – 2 Yellow RTS status = On
DCD 1 – 2 Yellow DCD status = On
SYNC LOSS 1 – 2 Red Loss of synchronization on line
interface
– –