Chapter 2 Installation and Operation User's Manual
2-2 Pre-configuring for Network Management LRS-24 RADview/TDM
LRS CHASSIS SETUP
CHASSIS NAME :80
CHASSIS NUMBER :3380
CHASSIS LOCATION IS :*
CONTACT PERSON IS :JohnDoe
CM CARD SOFTWARE VER :3.0 MAIN CARD HW REV :VER 1.0
INTERFACE CARD HW REV :0.0
TIME: (HH:MM:SS) :17:43:06 DATE:(YYYY-MM-DD): 2003-01-03
IP ADDRESS :172.017.152.080 IP MASK :255.255.255.000
READ COMMUNITY :PUBLIC
TRAP COMMUNITY :PUBLIC
READ/WRITE COMMUNITY :PUBLIC
DEFAULT GATEWAY :172.017.152.001
BURN IN MAC ADDRESS :0020D2FD8D40 BOOTP ON/OFF :OFF
BOOTP TIME OUT :3 sec BOOTP RETRIES :30
CHASSIS IP MODE :MULTIPLE
SERIAL LINE PROTOCOL :RS232
STATION CLOCK :EXTERNAL-AMI CLOCK
Figure 2-1. LRS-24 Chassis Setup
Table 2-1. LRS Chassis Setup - System Configuration Command Fields
Parameter Possible Values / Remarks
Chassis Name Logical name assigned to the LRS-24 unit.
Maximum 10 alphanumeric characters
Default: LRS-24
Chassis Number LRS-24 management number. The two least significant digits are displayed on the
Stat/Add display located on the front panel of the CM-2 module.
Maximum four hexadecimal digits
Default: 5544
Chassis Location Is Concise description of the chassis location
Maximum 20 alphanumeric characters
Contact Person Is Name of the person to be notified in case of problems / contact information.
Maximum 20 alphanumeric characters
CM Card Software
Version
Software version of CM-2 module.
Main Card HW Rev Hardware version of CM-2 module.
Interface Card HW Rev Hardware version of CM-2 interface module
Time Time of internal CM-2 real-time clock (the time is correct for the instant the
command has been received by the CM-2 module).
To change the time, type the correct time according to the format: hh:mm:ss.
Set the time at least one minute beyond the current time, so as to be able to
press <Enter> at the correct instant after completing all the fields on the data
form.
Vista de pagina 13