User's Manual Chapter 3 Configuration Management
LRS-24 RADview/TDM Setting Operational Parameters 3-53
Table 3-21. SHDSL Line Status Parameters
Parameter Possible Values / Remarks
Near-End Slot The name of the selected slot (IO-1…IO-12 ).
Read-only
Modem Near-End (1/2/3/4)
or
Far-End (5/6/7/8), according to selected modem.
Read-only
Type The modem type.
ASMi-52, ASMi-52CD, ASMi-52CD/4w, ASMi-52CQ
Read-only
SHDSL Mode The SHDSL Mode, relevant for
ASMi-52, ASMi-52CD, ASMi-52CD/4w, ASMi-52CQ card
STU-C or STU-R
Read-only
Far-End Type FCD-IP= fcdIp(9), DXC= dxcCard4p(10) or dxcCard8p(11), LRS-52=
lrs52(12), ASMi52/SA = sa(3), ASMi-52CD=double(5), ASMi-52CD4w=
double4W(13), ASMi-52CQ=quad(7)
Read-only
Far-End Modem Port
No.
The far-end modem number.
If far end unit is:
LRS double card: far end modem no. (1-2)
LRS quad card: far end modem no. (1-4)
DXC D8SL card: external port no.(1-8)
LRS-52 modem rack: 1-24
Read-only
Line Rate (Kbps) The line rate in kbps.
MIB values are in bps.
Divide by 1000 to display in Kbps (round to the nearest integer)
Read-only
Normal, Reversed
Read-only
Tip Ring
When Wires per Link=4 (modemWire = w4wire),
The following fields are displayed in two columns, the left column for
Line A, and the right column for Line B. Each column has its respective
title: LINE A, LINE B.
(When Wires per Link=2, then only one column, without a title, is
displayed.)
Read-only