Installation and Operation Manual Chapter 1 Introduction
Egate-100 Ver. 4.0 Functional Description 1-29
bridge port is shut down. Egate-100 continues to send loop detection frames,
and detects the end of the loop after three consecutive loop detection frames do
not return, upon which transmission resumes at the bridge port.
Diagnostics
Several types of diagnostics and troubleshooting procedures are available:
Ping test and self-test
E1/T1 PRBS tests for E1/T1
Events/traps.
Alarms and traps can be masked by user configuration.
For more information, refer to
Chapter 5
.
Hierarchically-layered traps/alarms – events resulting from events that were
already reported and are still active – are not sent. For example, LOF event traps
are not sent if LOS was sent and the physical layer problem persists.
Statistics Collection
Egate-100 provides the following diagnostic information:
Statistics for physical ports, logical ports, bridge ports, flows and RADIUS
Active alarms and a log file at STM-1/OC-3, channelized T3, Gigabit Ethernet, and
system levels.
For more information about monitoring statistics, see
Chapter 5
.
Configuration Reset
When required, the Egate-100 configuration parameters can be reset to their
default values. In addition to resetting to the factory-set values, Egate-100 allows
you to save the current settings as the device default settings, replacing the original
factory default settings. It is then possible to return to the saved settings when
using the Reset to Factory Defaults option from the configuration menu.
When required, the saved settings can be erased completely, restored the default
settings to the original factory default values.