Installation and Operation Manual Chapter 7 Application Tutorial
Egate-100 Ver. 4.0 IP DSLAM and WiMAX Backhauling over SDH/SONET 7-27
Connecting to Power
Egate-100 can be ordered with either AC power or DC power (single or dual
power supply).
Connecting to AC Power
AC power is supplied to Egate-100 via a standard 3-prong plug.
AC power should be supplied through the 1.5m (5 ft) standard power cable
terminated by a 3-prong plug. The cable is provided with the unit.
Before connecting or disconnecting any communication cable, the unit must be
grounded by connecting its power cord to a power outlet with a ground terminal,
and by connecting the ground terminal on the panel (if provided) to a protective
ground.
Interrupting the protective (ground) conductor inside or outside the unit, or
disconnecting the protective ground terminal may render this unit dangerous.
Intentional interruption is prohibited.
If the Egate-100 unit is equipped with two hot-swappable power supplies,
DO NOT install AC and DC power supplies together in the same unit.
³ To connect AC power:
1. Verify that the AC outlet is grounded properly. Ensure that the supply voltage
is in the range 100 VAC to 240 VAC
2. Connect the power cable to a power connector on the Egate-100 front panel.
3. Connect the power cable to the mains.
The unit turns on automatically.
Connecting to DC Power
³ To connect DC power:
Refer to the DC power supply connection supplement, located on the Technical
Documentation CD or at the end of this manual. Also, refer to the safety
instructions at the beginning of this document.
Configuring the Egate-100
This section describes the configuration of the Egate-100 unit as it appears in
Figure
7-1
. The configuration stages are:
Setting System Parameters
Setting Ethernet Parameters
Setting SDH/SONET Parameters
Setting Logical Layer Parameters
Setting Bridge Parameters
Warning