Chapter 4 Configuration Installation and Operation Manual
4-30 Configuring Egate-100 for Operation Egate-100 Ver. 4.0
The Protection menu appears.
2. From the Protection menu, choose APS.
The APS menu appears as illustrated in
Figure
4-30
.
3. Enable Protection. To do so, select Protection, and then select Yes.
Additional parameters appear as illustrated in
Figure
4-30
.
4. Configure APS parameters according to
Table
4-10
.
5. Select Save.
Egate-100
Main Menu> Configuration> System> Protection> APS
1. Protection > (Yes)
2. Mode > (1+1 optim. bidirectional)
3. Working Port > (1)
4. Wait to Restore (sec)[1-720]...(300)
5. Command > (No Command)
6. Flip upon SD > (No)
>
Please select item <1 to 6>
S - Save
ESC-prev.menu; !-main menu; &-exit
Figure
4-30. APS Configuration Menu
Table
4-10. APS Parameters
Parameter Description Possible Values
Protection Activate or deactivate APS protection
Default: No
Yes
No
Mode APS mode
Default: 1+1 optimized bidirectional
1+1 optimized bidirectional
Uni-directional
Working Port Port to receive data
Default: 1
1
2
Wait to Restore
(sec)
Number of seconds after link recovery before the
next protection switch is possible.
Default: 300
1 – 720
Command Clear. Removes the previous command.
Lockout of Protection. Prevents possible APS
switching.
Force Switch. Moves the active link to the next
port. This option is available for
1+1 Bi-Optimized Bidirectional only.
No Command. This is the default until a
command is selected.
Clear
Lockout of Protection
Force Switch
Flip upon SD
Whether the two ports flip in the event of signal
Yes
Vista de pagina 121
1 2 ... 117 118 119 120 121 122 123 124 125 126 127 ... 317 318

Comentarios a estos manuales

Sin comentarios