RAD Data comm 100 Especificaciones Pagina 218

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 318
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 217
Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-14 Detecting Problems Egate-100 Ver. 4.0
Alarm/Event Source Description
LVC 1..63
LVC 1..84
SDH LVC 1-63 level alarms
SONET LVC 1-84 level alarms
CH 1..63(84) E1-/T1-level alarms (63 for SDH / 84 for SONET)
P1 GIGA 1GBE port 1 alarms
P2 GIGA 1GBE port 2 alarms
ETH MNG Ethernet management port alarms
Logical 1.. 126 Logical-level alarms
Bridge 1.. 130 Bridge port-level alarms
EVENT Non-alarm events
Table
5-6. Sources for Alarms and Events (T3)
Alarm/Event Source Description
DEVICE System alarms and events
CH 1..63(84) E1-/T1-level alarms (63 for SDH / 84 for SONET)
T3 1..3 T3 level alarms
P1 GIGA 1GBE port 1 alarms
P2 GIGA 1GBE port 2 alarms
ETH MNG Ethernet management port alarms
Logical 1.. 126 Logical-level alarms
Bridge 1.. 130 Bridge port-level alarms
EVENT Non-alarm events
Table
5-7. Device Alarms List
Code Event Description
3 Self test failure The self test failed for unspecified reasons
4 Power Supply 1 failure Power supply 1 failed
5 Power Supply 2 failure Power supply 2 failed
6 Fan 1 failure Fan 1 failed
7 Fan 2 failure Fan 2 failed
12 Master clock failure The master clock failed
13 Fallback clock failure The fallback clock failed
14 PS types mismatch The power supply types are not identical, thus
the second power supply cannot take over if the
fist one fails.
Vista de pagina 217
1 2 ... 213 214 215 216 217 218 219 220 221 222 223 ... 317 318

Comentarios a estos manuales

Sin comentarios