Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Configuring Egate-100 for Management 4-9
Defining Host Parameters
Egate-100 can be managed using a network management station connected to
the Gigabit Ethernet network. In order to establish a proper connection, it is
necessary to configure the following: Host IP address, subnet mask, default
gateway, its trap, read and write communities.
³ To define the host IP parameters:
1. Navigate to Main Menu > Configuration > System > Management, and then
select Host.
The Host menu appears as illustrated in
Figure
4-6
.
2. Set the IP parameters according to
Table
4-5
:
Egate-100
Main Menu> Configuration> System> Management> Host
1. IP Address ... (0.0.0.0)
2. IP Mask ... (0.0.0.0)
3. Default Gateway ... (0.0.0.0)
4. Read Community ... (public)
5. Write Community ... ()
6. Trap Community ... ()
7. Encapsulation >
Please select item <1 to 7>
ESC-prev.menu; !-main menu; &-exit
Figure
4-6. Host Menu
Table
4-5. Host IP Parameters
Parameter Description Possible Values
IP Address Host IP address
Default: 0.0.0.0
0.0.0.0 to
255.255.255.255
IP Mask Host IP subnet mask
Default: 0.0.0.0
0.0.0.0 to
255.255.255.255
Default Gateway Specifies the default gateway
server’s IP address associated with
the subnet to which Egate-100
belongs.
Default: 0.0.0.0
0.0.0.0 to
255.255.255.255
To assign an IP address the first time the unit is powered up, or after resetting
the unit to the factory default, you must connect an ASCII terminal to the
CONTROL interface and use HyperTerminal to access the Egate-100 menus.
Note