Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Configuring Egate-100 for Operation 4-47
Parameter Description Possible Values
error is detected in the incoming signal. The BIP
information is collected using the B1 byte in
the Section Overhead.
Path UAS – Number of path unavailable
seconds (UAS) in the current interval. An
unavailable second is any second in which one
or more SEF defects were detected.
FE-Path ES – FE-Path ES threshold value for
sending event log and trap
FE-Path SES – Number of far end path severely
errored seconds (SES) in the current interval. A
second is considered to be a severely errored
second if multiple error events of the types
described for ES occurred.
FE-Path CV - Number of far end path coding
violations (CV) in the current interval: a coding
violation is declared when a Bit Interleaved
Parity (BIP) error is detected in the incoming
signal. The BIP information is collected using
the B1 byte in the Section Overhead.
FE-Path UAS – Number of far end path
unavailable seconds (UAS) in the current
interval. An unavailable second is any second in
which one or more SEF defects were detected.
Rising Specifies the alarm
rising threshold.
The selected event
is triggered when
the defined rising
threshold is crossed
Default: 0
0-65535
Falling Specifies the alarm
falling threshold.
The selected event
is triggered when
the defined falling
threshold is crossed
Default: 0
0-65535
³ To configure SDH/SONET LVC:
1. Navigate to Main Menu > Configuration > Physical Layer >SDH/SONET > LVC.