Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Additional Tasks 4-87
Egate-100
Monitoring> System> Connected Managers
Index IP Address Terminal Type User Name
0 0.0.0.0 UART SU
1 192.144.162.121 TELNET SU
2 172.55.144.60 SSH SU
3 172.55.144.60 SSL User
ESC-prev.menu; !-main menu; &-exit
Figure
4-90. Connected Managers Menu
Table
4-38. Connected Managers Parameters
Parameter Description
Index Manager’s serial number in the list of managers
IP Address IP Address of the manager connecting remote agent.
For UART this field is not used.
Terminal Type Manager’s terminal type
(UART, TELNET, WEB, SSL, or SSH)
User Name Egate-100 login user name
Viewing SNTP Status
You can view the system date and time, as well as SNTP information.
³ To view SNTP status:
1. Follow the path: Monitoring > System > SNTP.
The Monitoring SNTP menu appears as illustrated in
Figure
4-91
.
2. To display the list of NTP Servers, select NTP Servers.
The Monitoring NTP Servers menu appears as illustrated in
Figure
4-92
.
Egate-100
Monitoring> System> SNTP
System Uptime ... (00:02:17:10)
System Date ... (2008:09:01)
System Time ... (20:11:07)
Current Source ... (127.0.0.1)
1. NTP Servers >
>
Please select item <1 to 1>
ESC-prev.menu; !-main menu; &-exit
Figure
4-91. Monitoring SNTP Menu