Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Additional Tasks 4-89
Viewing APS Status
³ To view APS status for STM-1/OC-3:
1. Follow the path: Main Menu> Monitoring > System.
The Monitoring System menu appears as illustrated in
Figure
4-1
through
Figure
4-88
, depending on the status of APS and Ethernet Link
aggregation. If the Monitoring System menu does not contain APS or
Protection, then APS is not enabled.
If the Monitoring System menu contains APS, select it.
The System APS status menu appears as illustrated in
Figure
4-94
.
If the Monitoring System menu contains Protection, select it and then
select APS from the Monitoring System Protection menu (
Figure
4-93
).
The System APS status menu appears as illustrated in
Figure
4-94
.
2. Select Signal Fail & Degrade for status per port as illustrated in
Figure
4-95
.
3. Select Total Counter for current status and cumulative counts of mode
mismatch, channel mismatch, switch-byte failure, and FE-protection-line
failure, as illustrated in
Figure
4-96
.
Egate-100
Monitoring> System> APS (or Monitoring> System> Protection>APS)
APS Mode > (1+1 optimized bidirectional)
Current Working Port > (1)
RX K1K2(Hex) (0000)
TX K1K2(Hex) (0000)
1. Signal Fail & Degrade []
2. Total Counter []
3. Clear Counters
>
Please select item <1 to 3>
F – Forwards; B - Backwards
ESC-prev.menu; !-main menu; &-exit
Figure
4-94. APS Status Menu