Chapter 4 Configuration Installation and Operation Manual
4-56 Configuring Egate-100 for Operation Egate-100 Ver. 4.0
• PPP/BCP (PPP over HDLC)
• Ethernet over MLPPP over n x E1/T1
• GFP (non-VCAT, non-LCAS). You can configure whether Egate-100 expects
GFP frames to have VCAT headers, to enable interoperability with devices that
do not support G.8040, such as MiRIC.
• GFP (VCAT LCAS)
• Virtual Concatenation Group (VCG).
In order to define an MLPPP (multi-link PPP) logical port, you must first define a
set of PPP logical ports over E1/T1, and then attach (bind) up to eight such PPP
logical ports to the MLPPP port. The MLPPP port is then bound to a bridge port.
In order to define a GFP (VCAT LCAS) port, you must first define a VCG logical port
over E1/T1, and then attach (bind) the VCG logical port to the GFP port. The GFP
port is then bound to a bridge port.
In order to change or delete any logical ports, you must first erase any
associations with a bridge port.
Configuring Logical Ports
³ To configure the logical ports:
1. Navigate to Main Menu > Configuration > Logical Layer
The Logical Layer menu appears.
2. From the Logical Layer menu, select Logical Port.
The Logical Port menu (E1 or T1) appears as illustrated in
Figure
4-54
through
Figure
4-60
, according to the selected protocol type.
Egate-100
Main Menu> Configuration> Logical Layer> Logical Port
1. Port Number[1 - 144] ... (5)
2. Port Name ... (Central)
3. Protocol Type > (HDLC)
4. Physical Port Number[1 - 84] ... (5)
5. HDLC Flags[1-7] ... (1)
6. Alarms > (Unmasked)
7. Queue Profile Name ... ()
Please select item <1 to 5>
F - Forward Port; B - Backward Port; R - Remove Port
ESC-prev.menu; !-main menu; &-exit
Figure
4-54. Logical Port Menu – HDLC (E1)