Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Configuring Egate-100 for Operation 4-49
Parameter Description Possible Values
Alarms Low VC level, per VC12 or VT1.5
link. Range of links can be set.
For VC12: 1-63; For VT1.5: 1-84
For each port, or range of ports,
select the port number and specify
whether to mask or unmask alarms
Default: Unmasked
Masked
Unmasked
³ To configure LVC event threshold:
1. Navigate to Main Menu > Configuration > Physical Layer >SDH/SONET > LVC
and select Event Threshold.
The LVC Event Threshold menu appears as illustrated in
Figure
4-46.
Egate-100
Main Menu> Configuration> Physical Layer> SDH/SONET> >LVC
>Event Threshold (LVC Number 1)
Counter Rising Falling
Trib ES (0) (0)
Trib SES (0) (0)
Trib CV (0) (0)
Trib UAS (0) (0)
FE-Trib ES (0) (0)
FE-Trib SES (0) (0)
FE-Trib CV (0) (0)
FE-Trib UAS (0) (0)
1. Change Cell [0-65535]
>
Please select item <1 to 1>
F - Forward; B - Backward
ESC-prev.menu; !-main menu; &-exit
Figure
4-46. LVC Event Threshold Menu
2. Configure event threshold parameters according to
Table
4-23.
Table
4-23. LVC Event Threshold Parameters
Parameter Description Possible Values
Counter Displays the event
threshold counter
Trib ES – Trib ES threshold value for sending
event log and trap.
Trib SES – Number of tributary severely errored
seconds (SES) in the current interval. A second
is considered to be a severely errored second if
multiple error events of the types described for
ES occurred.
Trib CV - Number of tributary coding violations
(CV) in the current interval: a coding violation is
declared when a Bit Interleaved Parity (BIP)