Chapter 7 Application Tutorial Installation and Operation Manual
7-28 IP DSLAM and WiMAX Backhauling over SDH/SONET Egate-100 Ver. 4.0
Setting System Parameters
Make sure that Egate-100 is properly installed and connected to an ASCII
terminal.
³ To set the host parameters:
1. Display the Host menu (Configuration>System>Management>Host), and
configure the host parameters as illustrated in
Figure
7-9
.
2. To define host VLAN tagging, in the Host menu select Encapsulation to
navigate to the Encapsulation menu.
3. Configure the host encapsulation parameters as illustrated in
Figure
7-37
.
Egate-100
Main Menu> Configuration> System> Management> Host>
Encapsulation
1. Host Tagging > (Tagged)
2. Host VLAN ID[1 - 4094] ... (500)
3. Host Priority Tag[0 - 7] ... (0)
Please select item <1 to 3>
ESC-prev.menu; !-main menu; &-exit
Figure
7-37. Configuring Host Encapsulation
³ To add the network manager:
1. In the Manager List menu (Main Menu > Configuration > System >
Management > Manager List), move the cursor to the Manager IP cell you
wish to change by clicking <Tab>.
The selected cell is highlighted and the value is displayed in the Change
Cell field.
2. Select Change Cell, and enter 192.188.10.12 for the selected network
manager.
³ To configure the system clock source:
1. Navigate to the master clock source menu (Main Menu>Configuration>
System>Clock Source>Master Clock) and configure the parameter values as
illustrated in
Figure
7-38
.
2. Navigate to the fallback clock source menu (Main Menu>Configuration>
System>Clock Source>Fallback Clock) and configure the parameter values as
illustrated in
Figure
7-39
.