Chapter 4 Configuration Installation and Operation Manual
4-24 Configuring for Operation ASMi-52 Ver. 2.8
ASMi-52
E1 Local Port
Framed mode (G732N)
Sync mode (CCITT(complies with G732))
CRC-4 (NO)
Idle code (ff)
Time slots assign
Unit Identical Set (Yes)
Number TS for remote E1
Save
>
ESC-prev. menu; !-main menu; &-exit; @-scroll
Figure
4-26. E1 Local Port Menu
ASMi-52
E1 Remote Port
Framed mode (G732N)
Sync mode (CCITT (complies with G732))
CRC-4 (NO)
Idle code (ff)
1. Time slots assign
2. Save
>
ESC-prev. menu; !-main menu; &-exit; @-scroll
Figure
4-27. E1 Remote Port Menu
Selecting E1 Framing Mode
The Framing mode is configurable if one of the conditions below is fulfilled.
If the local ASMi-52 is configured as CO,
if the local ASMi-52 is configured as CPE and the remote is not an E1 modem.
The remote ASMi-52 is configurable if the local is configured as CO and is not
an E1 modem
If Frame Mode is Unframed, then the remaining E1 parameters are disabled.
³ To select E1 framing mode:
1. From the E1 Local Port menu, select Framed Mode (Main menu >
Configuration > E1 Configuration > E1 Local Port > Framed Mode).
The Framed Mode menu appears (see
Figure
4-28
).
2. From the Framed Mode menu, select Unframed, G732N, or G732S
transparent.
The E1 Local Port menu appears.
Notes