RAD Data comm ASMi-52L Especificaciones Pagina 75

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 184
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 74
Installation and Operation Manual Chapter 4 Configuration
ASMi-52 Ver. 2.8 Configuring ASMi-52 for Management 4-7
ASMi-52
VLAN Encapsulation
1. Host Tagging (UNTAGGED)
2. VLAN management ID [1 – 4094] (1)
3. VLAN priority (0-7) (0)
>
ESC-prev. menu; !-main menu; &-exit; @-scroll
Figure
4-9. VLAN Encapsulation Menu
Configuring Control Port Parameters
The embedded ASMi-52 software enables you to configure the Control port
parameters.
³ To access the Control port menu:
From the System Configuration menu, select Control Port (Main menu >
Configuration > System Configuration > Control Port).
The Control Port menu appears (see
Figure
4-10
)
ASMi-52
Control Port
Rate >(9600 bps)
Interface (DCE)
CTS (=RTS)
DSR (DTR)
Port Control >
Save
>
ESC-prev. menu; !-main menu; &-exit; @-scroll
Figure
4-10. Control Port Menu
Changing the Control Port Data Rate
The control port of ASMi-52 supports different data rates that can be configured
via the Rate menu (see
Figure
4-11
).
³ To configure the control port data rate:
1. From the Control Port menu, select Rate (Main menu > Configuration >
System Configuration > Control Port > Rate).
The Rate menu appears (see
Figure
4-11
).
2. Select the terminal rate by typing the number corresponding the required
value, and press <Enter>.
3. Select Save to save the changes.
Vista de pagina 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 183 184

Comentarios a estos manuales

Sin comentarios