Chapter 2 Installation and Operation Installation and Operation Manual
2-8 Operating the ASM-40CD ASM-40CD Ver. 1.0
Powering ASM-40CD Up
To power ASM-40CD up:
Turn on the LRS-24 modem racks on both sides of the line.
After power-up, all LEDs are lit up for 3 seconds while the CPU initiates
the ASM-40CD module.
After synchronization between the two modems has been achieved, the
ASM-40CD module assumes the normal state according to the LED
indications in
Table 2-6
.
Normal Operation
After power-up the LEDs should assume the states as shown in
Table 2-6.
For
other LED indications, see
Table 2-5
.
Table 2-6. Normal LED Indications
ID Color State Notes
POWER Green ON ASM-40CD is powered-up
TD Yellow TD LED state depends on local DTE transmission
RD Yellow RD LED depends on remote DTE transmission
RTS Yellow Indicates RTS from DTE
DCD Yellow ON Indicates signal detection on the line
SYNC LOSS Red Loss of synchronization
TEST Red OFF
ERR Red OFF If ERR LED is ON – check alarm buffer to determine
problem