Installation and Operation Manual Chapter 2 Installation and Operation
ASM-40CD Ver. 1.0 Installing the Interface Module 2-3
Table 2-1. ASM-40CD Fuses
Fuse Function
F1, F2 1A for the 135V phantom power supply line
F3 1A for the -5V power supply
F4 1A for the +5V power supply
F5 500 mA for phantom of the modem 1 power supply
F6 500 mA for phantom of the modem 2 power supply
Table 2-2
describes the backplane connectors, shown in
Figure 2-1
.
Table 2-2. Backplane Connectors
Connector Function Use
P10 Data Carrying data and signaling to/from the
interface module
P11 Control Coupling ASM-40CD module to the hub
control module
P12 Power Supplying +5V and –5V from the hub
power supply module
2.4 Installing the Interface Module
Interface Module Inspection
Check that the supplied interface module meets the physical and electrical
interface requirements of the installation site, according to
Table 2-3.
The
interface modules are:
LRSI-F-5 – V.24/RS-232 (64 kbps), V.35, X.21, RS-530 and V.36 interfaces
(via adapter cables), see
Figure 2-2
.
LRSI-F-14 – IR-ETH, IR-ETH/QN, see
Figure 2-3
.
For a more detailed description of the IR-ETH and IR-ETH/QN interface modules,
see
Appendix A
and
Appendix B
.
LRSI-F-xx interface modules are placed in the top section of the LRS-24F chassis;
LRSI-B-xx interface modules are placed in the back section of the LRS-24B
chassis.
Note