10 Rockwell Automation Publication 750-TD001H-EN-P - June 2013
PowerFlex 750-Series AC Drives
Control Method: Sine coded PWM with programmable carrier frequency. Ratings apply to all drives.
Carrier Frequency: Default Settings:
Frames 1…4:
Frames 5…10:
Settings:
Frames 1…6:
Frame 7:
Frames 8…10:
4 kHz
2 kHz
2, 4, 8, 12 kHz
2, 4, 8 kHz
2, 4 kHz
Output Voltage Range: 0 to rated motor voltage
Output Frequency Range: 0…325 Hz @ 2 kHz carrier
0…650 Hz @ 4 kHz carrier
Frequency Accuracy
Digital Input:
Analog Input:
Within ±0.01% of set output frequency
Within ±0.4% of maximum output frequency
Frequency Control: Speed regulation - with Slip Compensation (V/Hz & Sensorless Vector modes)
0.5% of base speed across 40:1 speed range, 40:1 operating range
Speed Control: Without feedback (Flux Vector mode), 0.1% of base speed across 100:1 speed range, 120:1 operating range,
50 rad/sec bandwidth
With feedback (Flux Vector mode), 0.001% of base speed across 100:1 speed range, 1000:1 operating range,
190 rad/sec bandwidth
Torque Regulation: Without feedback (Flux Vector mode), ±5%, 600 rad/sec bandwidth
With feedback (Flux Vector mode), ±2%, 2500 rad/sec bandwidth
Selectable Motor Control: - Standard V/Hz with full custom capability
- Sensorless Vector with full tuning
- Flux Vector with and without a feedback device
- Induction motor control
- Surface mount permanent magnet motor control with encoder feedback (Frames 1…10)
- Surface mount permanent magnet motor control without encoder feedback (Frames 1…7)
- Internal permanent magnet motor control with encoder feedback (Frames 1…10)
Stop Modes: Multiple programmable stop modes including - Ramp, Coast, DC-Brake, Ramp-to-Hold, Fast Braking, and
Current Limit Stop.
Accel/Decel: Two independently programmable accel and decel times. Each time may be programmed from 0 to 3600
seconds in 0.1 second increments (0 to motor nameplate speed).
S Curve Time Adjustable from 0 to 100% of ramp time (normal duty rating)
Intermittent Overload:
Light Duty (Frames 8…10 Only)
Normal Duty
Heavy Duty
110% Overload capability for up to 1 minute out of 10 minutes
110% Overload capability for up to 1 minute out of 10 minutes
150% Overload capability for up to 3 seconds out of 60 seconds
150% Overload capability for up to 1 minute out of 10 minutes
180% Overload capability for up to 3 seconds out of 60 seconds
Current Limit Capability: Proactive Current Limit programmable from 20 to 160% of rated output current. Independently
programmable proportional and integral gain.
Electronic Motor Overload Protection: Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection
according to NEC article 430.126 (A)(2). UL 508C File E59272.