Chapter 5 Setup Menu FCD-IPM Installation and Operation Manual
5-70 Interface Parameters Menu
Table 5-24. Frame Relay Link Parameters
Parameters Description
Self Learn
DLCI/Maintenance
Specifies whether FCD-IPM will self learn the maintenance protocol on the
Frame Relay link and the existing DLCIs with their status (UP or DOWN).
When this parameter is disabled (OFF), you need to configure the
maintenance protocol and the DLCIs manually.
CLLM Status Specifies whether CLLM frames, used for congestion indication, will be
supported (ON) or not (OFF).
Maintenance Protocol Specifies the maintenance protocol of the Frame Relay link: T1.617/ANNEX
D, Q.933/ANNEX A, LMI or None. This parameter can only be configured if
Self learn DLCI /Maintenance parameter is disabled (OFF).
Polling Interval Specifies the number of seconds between transmission of two successive status
enquiry frames.
Full Enquiry Interval Specifies the number of polling intervals after which a full status request frame
is transmitted.
Error Threshold Specifies the number of unacknowledged monitored events (status enquiry
frames and full status enquiry frames) that can occur in a sliding monitored
events window before the link is declared DOWN.
Monitored Events Specifies the number of monitored events (status enquiry frames and full status
enquiry frames) in a sliding monitored events window.