Installation and Operation Manual Quick Start Guide
ASM-40 Ver. 1.0 Operating ASM-40 3
DIP Switch Function Possible Settings Factory
Setting
J4, CHASS Controls the connection
between the ASM-40 signal
ground and the frame (chassis)
ground
CON – Signal ground is connected to the frame
ground
DIS – Signal ground is disconnected from the
frame ground
CON
Note: Disconnecting the signal ground from the frame ground may render the unit unsafe for connection to
unprotected telecommunication networks in some locations.
Connecting the Cables
Connecting the Line
To connect the line:
Connect the line cable to the rear panel line connector.
Connecting the DTE
To connect the DTE:
Connect the DTE cable to the appropriate ASM-40 rear panel connector.
Connecting the Power
To connect AC power to ASM-40:
1. Connect the power cable to the power connector on the ASM-40 rear panel.
2. Connect the power cable to the mains outlet.
The unit turns on automatically upon connection to the mains.
To connect DC power to ASM-40:
Refer to
DC Power Supply Connection Supplement
.
2. Operating ASM-40
ASM-40 does not require operator attention once installed and configured.
Verifying Performance
When data is being transferred, observe that the following front panel LEDs light
or blink:
PWR: On
RTS: On
TD: Flashing or Off
RD: Flashing or Off