5620 Model Descriptor for LA-110 User’s Manual Chapter 4 Port Configuration and Monitoring
SHDSL Port Configuration 4-41
Table 4-21. SHDSL Port – Physical Layer Status Parameters
Parameter Remarks
Port The selected port
SHDSL
Read-only
Type The protocol application which runs above the physical port.
SHDSL
Read-only
Bit Rate An estimate of the interface's current bandwidth in bits per second.
Read-only
DSP Version The version of the SHDSL standard implemented as reported in an Inventory Response
message.
Read-only
Vendor SW
Version
Vendor software version as reported in an Inventory Response message.
Read-only
Loop
Attenuation (dB)
The current loop attenuation for this endpoint as reported in a Network or Customer
Side Performance Status message.
Read-only
SNR Margin (dB) The current SNR margin for this endpoint as reported in a Status Response/SNR message.
Read-only
No Defect The current state of the endpoint.
On, Off
Read-only
Power Back Off The current state of the endpoint.
On, Off
Read-only
SNR Margin
Alarms
Displays the signal/noise margin in dB, measured at the instant the command has been
received by LA-110.
On, Off
Read-only
Loop
Attenuation
Alarm
Displays the loop attenuation threshold in dB, measured at the instant the command has
been received by LA-110.
On, Off
Read-only