5620 Model Descriptor for LA-110 User’s Manual Chapter 5 Cross Connection
Configuring Cross Connections 5-21
Figure 5-11. FR VC Connections Info
Table 5-13. FR VC Connections Info Parameters
Parameter Valid Ranges/Remarks
ID The row/index number.
VPI The VPI value of the VC.
0…31
Read-only
VCI The VCI value of the VC.
0…255
Read-only
SSCS DLCI Read-only
Operation Status
Up, Down
Read-only
IWF
0…42
Read-only
IWF Type
Network, Service
Read-only
Traffic Descriptor
1…200
Read-only
Continuity Check
On, Off, Send Only, Receive Only
Read-only
Last Change This field indicates the time of the last change on the port.
Read-only
Activating/Deactivating Connection
To activate/deactivate FR VC connections:
1. In the Navigator, select the necessary FR VC connection, right-click and select
Configure > Activate/Deactivate Connection.