RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 Especificaciones Pagina 82

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 90
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 81
Appendix B Traffic Separation RIC-155 Installation and Operation Manual
B-8 Configuring for a Typical Application
MNG
1
1
2
2
1
1
1
1
Local RIC-155
Switch
Remote RIC-155
2
22
2
Host Host
Uplink
Uplink
Data
Management
Station
LAN LAN
Data
Figure B-10. Managing RIC-155 via Data Port
The units are configured as follows:
Local RIC-155:
Forwarding – Filter Tagged
Port Management Access – All
Host Tagging – Tagged
Host VLAN – 1
Host VLAN Priority – any from 0 to 7
Management and data ports – Tag stripping is disabled
Uplink port – Tag.
Remote RIC-155:
Forwarding – Filter Tagged
Port Management Access – None
Host Tagging – Untagged
Management and data ports – Tag stripping is enabled
Uplink port – Stack.
Vista de pagina 81
1 2 ... 77 78 79 80 81 82 83 84 85 86 87 88 89 90

Comentarios a estos manuales

Sin comentarios