Chapter 2 Installation and Setup Installation and Operation Manual
2-4 Connecting to the ASCII Terminal LA-210 Ver. 1.5
CONTROL
DCE
LINK/ACT132 4
10/100BASE -T
SHDSL
12
Figure
2-2. 10/100BaseT Connectors
³ To connect to the user Ethernet equipment:
Connect LA-210 to the user Ethernet equipment using standard straight UTP
cables terminated with RJ-45 connectors.
2.7 Connecting to the ASCII Terminal
LA-210 can be connected to an ASCII terminal via a 9-pin D-type female
connector designated CONTROL. Refer to
Appendix A
for the connector pinout.
CONTROL
DCE
LINK/ACT132 4
10/100BASE -T
SHDSL
12
Figure
2-3. CONTROL Connector
³ To connect to an ASCII terminal:
1. Connect the male 9-pin D-type connector of CBL-DB9F-DB9M-STR straight
cable available from RAD to the CONTROL connector.
2. Connect the other connector of the CBL-DB9F-DB9M-STR cable to an ASCII
terminal.
Terminal cables must have a frame ground connection. Use ungrounded cables
when connecting a supervisory terminal to a DC-powered unit with floating
ground. Using improper terminal cable may result in damage to the supervisory
terminal port.
LA-210 units may be equipped with additional connectors that will be supported
by future software versions.
Note
Caution