Appendix D CM-2 Management Commands LRS-24 Installation and Operation Manual
D-12 Defining CM-2 Download Parameters
CHANGE CM2 SOFTWARE VERSION
CM2 containing the following versions:
ID Version No. Date Size Location
1 3.0 2000- 3- 8 353k FLASH1
2 3.0 2000- 3- 8 353k FLASH2
3 3.0 2000- 2-16 353k EPROM
Please choose the ID number
1. ID NUMBER: 2
2. Password: This field is not applicable
To change the ID number press f to scroll forward
or b to scroll backward
NOTE: the first version (ID number 1) is the one we will run from
Figure D-7. Change CM2 Software Version
2. Press <F> (forward) or <B> (backward) to select the ID Number of the
version you want to run.
3. To exit the screen, without changing parameters, press <Esc>.
Type the parameter data, and press <Enter> to start the download process. When
a version is selected, the CM-2 resets, and loads the chosen version. The CM-2’s
seven-segment screen displays a rotating o until the reboot is complete.
View CM-2 Software Version
To view CM-2 Software Version:
1. Type 5.
The View CM2 Software Version screen appears.