RADview FCD-IP User’s Manual Chapter 3 Port Management
Configuring Protocol Parameters 3-31
Figure 3-21. DLCI Table
Table 3-20. DLCI Table Parameters
Parameter Possible Values / Remarks
Interface The selected interface.
DLCI # Specifies DLCI number.
State Specifies state of DLCI.
Active, Inactive (for receive/transmit)
CIR Value Specifies maximum number of data bits that the network guarantees to transfer
during the measurement interval.
Excess Value Specifies maximum number of uncommitted data bits the network attempts to
deliver during measurement interval.
Throughput Value Specifies the average number of data bits pre second transferred by the network.
When CIR is defined as one second, Throughput Value should also be one second.
To add an entry to the DLCI Table:
1. In the DLCI Table, click <Add...>.
The Add DLCI dialog box appears.
2. Configure the desired parameters (see Table 3-20).
3. Click <Set>.