Vmux-2100 Installation and Operation Manual Chapter 3 Operation
Default Settings 3-5
Table 3-3. Vmux-2100 Default Settings (Cont.)
Parameter Default Value
External E1
Connect No
Frame 732S
Restoration Time 1 second
Clock Source Lbt
Interface Type Ltu
Idle Code ff
Signaling CAS
Profile 1
External T1
Connect No
Clock Source Lbt
Frame Esf
Interface Type Dsu
Line Code B8ZS
Rx Sensitivity (CSU mode only) LOW (-30 dB)
Tx Gain Level (CSU mode only) 0 dBm
Line Length (DSU mode only) 0-133 ft
Restoration Time 1 second
Idle Code ff
Signaling CAS
Profile 1
External Timeslot
Update from Time Slot 1
To Time Slot 1
Type N.C.
Bundle 1
Destination Port ID 1
Destination Time Slot 1