Installation and Operation Manual Chapter 5 Monitoring and Diagnostics
Optimux-108 Ver. 6.1 Monitoring Performance 5-3
Table
5-2. System Status Parameters
Parameter Description
Device Number
Indicates the Optimux-108 currently being monitored:
Local
Remote
Device type Displays the device type
Redundancy status Indicates if redundancy is available or not available
Available – two uplinks are mounted
Not Available – only one uplink is mounted or Redundancy
mode is ‘OFF’
Redundancy mode The redundancy state of the system:
AUTO
MANUAL
OFF
The option is hidden when redundancy status is not available.
Force Link Indicates the main uplink
Active Link Identifies the currently active link
PS A Status The state of the Power Supply A:
OK
Fault
PS B Status The state of the Power Supply B:
OK
Fault
Alarm Indication Current system status:
Normal - System is functioning normally; no alarms activated
Major - One or more major alarms are currently activated
Minor - One or more minor alarms are currently activated
Test Indication Indicates whether any tests are currently active in the device:
ON - Tests are currently active in the device
OFF - No tests are currently running
³ To set the device to monitor:
Enter 1.
The Device Number toggles between Local and Remote, to indicate the
device currently being monitored.