Chapter 4 Diagnostics and Troubleshooting IPmux-11 Installation and Operation Manual
4-12 Performance Monitoring Statistics
Monitoring>Status>Connection
Destination IP address: (1.1.1.1)
Next hop MAC address: (000000000000)
Connectivity status: > (OK)
Sequence errors: (0)
Jitter buffer underflows: (0)
Jitter buffer overflows: (0)
1. Bundle ID ... (1)
>
ESC-prev.menu; !-main menu; &-exit 1 Mngr/s
Figure 4-9. Connection Screen
Table 4-4 lists the bundle connection parameters.
Table 4-4. Bundle Connection Parameters
Parameter Description
Destination IP
Address
The IP address of the opposite IPmux, to which the bundle is destined.
Next Hop MAC
Address
Layer 2 Applications: the MAC address displayed is the MAC address of the remote IPmux-11.
Layer 3 Applications: the MAC address displayed is the MAC address of the connected router.
Connectivity
Status
Disabled: No activity in the channel. The channel is disabled.
OK
: Both the remote and the local IPmux receive Ethernet frames, (however, there may be problems
such as sequence errors, underflows, overflows, as explained below).
Local Fail: The local IPmux-11 does not receive Ethernet frames.
Remote Fail
: The remote IPmux-11 does not receive Ethernet frames.
Unavailable: The remote IPmux-11 does not reply to OAM messages (only applicable when OAM is
enabled).
Validation Fail
: The remote IPmux-11 replies, but there is a configuration error (only applicable when
OAM is enabled).
Standby: Redundant bundle is OK and wiaitng for redundancy switching (only applicable when
Redundancy is enabled).
TDM Fail
: There is LOS/LOF at the TDM side (only applicable when Redundancy is enabled).
Note: While under Disable or Local Failure or Remote Failure status, the statistic counters will be
inactive.