RAD Data comm IPmux-8 Especificaciones Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 174
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
Installation and Operation Manual Chapter 2 Installation and Setup
IPmux-8/16 Ver. 6.00 Connecting to the Management Stations 2-7
ALARMSCONTROL DTE
IPmux-8
PS1 ALMPS2 RDY
Figure 2-9. CONTROL DTE Connector (IPmux-8)
PS1
RX
TX
LINK
COLL
IPmux-16
ALM
CONTROL ETH
PS2 RDY
CONTROL DTE
Figure 2-10. CONTROL DTE Connector (IPmux-16)
To connect to an ASCII terminal:
1. Connect one 9-pin D-type connector of CBL-DB9/DB9/NULL cable to the
CONTROL DTE connector.
2. Connect the other connector of the CBL-DB9/DB9/NULL cable to an ASCII
terminal.
Connecting to the Network Management Station
IPmux-16 is connected to an NMS via an 8-pin RJ-45 connector designated
CONTROL ETH. Refer to Appendix A for the connector pinout.
PS1
RX
TX
LINK
COLL
IPmux-16
ALM
CONTROL ETH
PS2 RDY
CONTROL DTE
Figure 2-11. CONTROL ETH Connector
To connect to an NMS:
Connect IPmux-16 to a hub or switch using a straight cable.
or
Connect IPmux-16 to a network interface card using a cross cable.
Connecting to the External Alarm Device
IPmux-8/16 is connected to an external alarm device via a 9-pin D-type female
connector designated ALARMS. Refer to Appendix A for the connector pinout.
ALARMSCONTROL DTE
IPmux-8
PS1 ALMPS2 RDY
Figure 2-12. ALARMS Connector (IPmux-8)
Vista de pagina 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 173 174

Comentarios a estos manuales

Sin comentarios