User's Manual Chapter 7 Fault Management
RADview-SC/TDMoIP IPmux-11 Monitoring Object Status 7-3
Viewing Active Alarms
The Alarms command enables you to view agent alarms from the time that the
selected IPmux-11 was turned on or from the last time the active alarm list was
cleared. Use this command to locate problems and as a troubleshooting aid.
To view the Active Alarm List:
Select Fault > Alarms...
The Active Alarm list appears.
Figure 7-2. Active Alarm List
Table 7-2. Active Alarm Parameters
Parameter Possible Values/Remarks
Slot
1
Port The type of port
T1/E1
Alarm The type of Alarm
Port alarms:
Far End LOF, Far End Sending AIS, Near End LOF, Near End Loss of Signal,
Near End Sending TS16 LOMF