Optimux-34, Optimux-25
Fiber multi
lexers for 16 E1/T1 and Ethernet
GENERAL
Diagnostics
Local and remote loopbacks on uplink and
on each E1/T1 port
Local loopback on optional V.35 user port
((Optimux-34 only)
Timing
Uplink: internal, loopback
E1/T1 port: transferred transparently,
independent for each channel
V.35: internal, external, loopback
Power
Standalone: wide range power supply
AC: 100 to 240 VAC
DC: -48 VDC (-40 to -125 VDC)
Card: supplied by LRS-102
Power Consumption
Standalone:
AC: 32 VA max
DC: 13W max
Card: 10.4W max
Physical
1U-high
Height: 4.4 cm (1.8 in)
Width: 44.0 cm (17.0 in)
Depth: 24.0 cm (9.0 in)
Weight: 3.5 kg (8.0 lb)
2U-high (Optimux-34 only)
Height: 8.8 cm (3.5 in)
Width: 44.0 cm (17.0 in)
Depth: 24.0 cm (9.0 in)
Weight: 4.0 kg (9.0 lb)
Card: fits into the LRS-102 rack
Environment
Temperature: 0°–50°C (32°–122°F)
Humidity: Up to 90%, non-condensing
Figure 3. Fanning out E1 Channels from Standard E3
Table 2. Optimux Comparison Table
Feature Optimux-108L
Optimux-108/106
Optimux-34/25
Optimux-134/125
Optimux-45/45L
Optimux-1551 Optimux-1553
Uplink Fiber Optic Fiber Optic
E3, Fiber Optic E3, Fiber Optic T3, Fiber Optic Copper,
STM-1/OC-3
Copper,
STM-1/OC-3
Bandwidth
(Mbps)
108 108/81 34/25 34/25 or 134/125
45 155 155
Number of
trunks
4 E1 4 E1/4 T1 16 E1/16T1
16 E1/16T1 21 E1/28 T1 21/42/63 E1
28/56/84 T1
3 E3/3 T3
Ethernet
support
9 9 9 9
– – –
Special
features
Reduced Power
Consumption
Cost-Effective
Redundant,
hot-swappable
uplinks
SFP-based uplinks
Full Bandwidth Ring support
(Optimux-45)
Full redundancy Full redundancy
Card
version for
LRS-102/
MP-4100
9 9 9
Supports
OP-34/25C
– – –