Optimux-XLT1 Installation and Operation Manual Chapter 4 Supervisory Port Software Configuration
The Optimux-XLT1 Device Information 4-5
Viewing the Optimux-XLT1 Component Status
To view the status of the functional blocks:
Type 2 in the Device Information Menu screen.
The Status Information screen appears.
LOCAL DEVICE
STATUS INFORMATION
------------------
Power supply 1 FAULT
Power supply 2 OK
Active Link MAIN
Link Redundancy MANUAL
Clock Source INTERNAL
0. Exit
Enter your choice:
The applicable states for power supplies are indicated in Table 4-1.
Table 4-1. Power Supply States
State Indicates
Not present Power supply is not mounted. This indication applies only
to power supply # 2 (backup)
OK Power supply is ON and functions properly
FAULT Power supply failure was detected