HS-RN MP-2100/2104 Ver. 12.6, MP-4100 Ver. 2.0 Configuration Procedure 1
Quick Start Guide
If you are familiar with the HS-RN module, use this guide to prepare it for
operation.
1. Preparation for Operation
Insert the module in the prescribed I/O slot.
Connect the prescribed cables to the module CH connectors, in accordance with
the site installation plan.
2. Configuration Procedure
³ To configure the desired HS-RN channel in the MP-2100/2104 chassis:
Use the command:
DEF CH SS CC
where SS is the slot number, and CC is the channel number (1 to 4).
³ To configure the desired HS-RN channel in the MP-4100 chassis:
Use the Configuration>Physical Layer>I/O screen.
Configuration parameters and the range of values are listed in the following table.
Parameter Range of Values
Connect*
YES
NO
Admin Status**
UP
DOWN
Bus Connection*
FULL
PARTIAL
Encapsulation Mode
Bandwidth Optimized
Latency Optimized
Format ASYNC (Default with MP-2100)
SYNC (Default with MP-4100)