RAD Data comm Megaplex-2100 Información técnica Pagina 116

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 168
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 115
Chapter 2 Agent Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
Mask/Invert Indicates mask/invert staus of alarm
Mask: No, No and Save, Yes, Yes and Save
Inverted: Yes, No
Counter Number of times that this alarm occurred since either Megaplex startup or the last time
the alarm list was cleared
[Save File…] Saves alarms list in a file. In the Save dialog box the default file name is output.alr. You
can change the filename.
[Clear] Clears all active alarms. Confirmation is not required.
Displaying System Level Alarms
To display a list of system level alarms:
From the Fault menu, select Alarms followed by Display and System Level…
The Mux Active Alarm List appears displaying active alarms for the current
Megaplex. The list begins from either Megaplex startup or from the last
time the alarm list was cleared. The order of alarms in the table can be
sorted by clicking on the column headers with an asterix “*”.
Figure 2-29. Mux Active Alarm List
Table 2-15. Mux Active Alarm Parameters
Parameter Possible Values / Remarks
No. Alarm No.
Code Code number of the alarm
2-28 Megaplex Level Fault Operations