MEGAPLEX-2100 I/O Modules
Multi-Channel Low-Speed Data Modules
LS-2 MTLS-2
LS-2A MTLS-2/2TS
LS-2A/2TS LS-2/M
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications. No part of this publication may
be reproduced in any form whatsoever without prior written approval by RAD Data Communications.
No representation or warranties for fitness for any purpose other than what is specifically mentioned in this manual is
made either by RAD Data Communications or its agents.
RAD Data Communications reserves the right to revise this publication and make changes without obligation to
notify any person of such revisions or changes.
For further information contact RAD Data Communications at the address below or contact your local distributor.
RAD data communications
Headquarters
12 Hanechoshet Street
Tel Aviv 69710 Israel
Tel: 972-3-6458181
Fax: 972-3-6498250
RAD data communications
US East
900 Corporate Drive
Mahwah, NJ 07430 USA
Tel: (201) 529-1100
Fax: (201) 529-5777
RAD data communications
US West
3631 South Harbor Boulevard
Suite 250
Santa Ana, CA 92704
Tel: (714) 850-0555
Fax: (714) 850-1555
© 1999 RAD Data Communications Publication No. 764-203-01/99
Vista de pagina 0
1 2 3 4 5 6 ... 51 52

Indice de contenidos

Pagina 1

MEGAPLEX-2100 I/O ModulesMulti-Channel Low-Speed Data ModulesLS-2 MTLS-2LS-2A MTLS-2/2TSLS-2A/2TS LS-2/MInstallation and Operation ManualNoticeThis ma

Pagina 2

Introduction1-4 MP2100M-LS-2 Modules - Installation and Operation Manualchannels, a group of two /X.58 modules can provideup to twelve 4.8 kbps channe

Pagina 3 - Table of Contents

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-5/SDM modules can provide up to twenty 2.4 kbpschannels. Other combinations of

Pagina 4 - Appendix A. Connection Data

Introduction1-6 MP2100M-LS-2 Modules - Installation and Operation Manual• Transmission of five synchronous or asynchronous 9.6 kbps channels, inone m

Pagina 5 - List of Figures

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-7Channel CharacteristicsChannel Data RatesThe channels of all the LS-2 module v

Pagina 6 - List of Tables

Introduction1-8 MP2100M-LS-2 Modules - Installation and Operation Manual• For DTE interfaces, the lines are used as follows: The RTS line is an outp

Pagina 7 - Chapter 1

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-9Because of the use of synchronous-to-asynchronous conversion, whenconfiguring

Pagina 8 - Versions

Introduction1-10 MP2100M-LS-2 Modules - Installation and Operation ManualManagement andDiagnosticsChannel data rates, as well as all the operating par

Pagina 9

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-111.2 System Planning ConsiderationsThis section explains the multiplexing for

Pagina 10 - Introduction

Introduction1-12 MP2100M-LS-2 Modules - Installation and Operation Manual16 User DataBits2 3 4 5 6 7 8S Bit(Status Bit)F Bit(Framing andHousekeeping)E

Pagina 11

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-13Envelope No.7 8 10 11 12 13 14 15 16 17 18 19 2091 2 3 4 5 6 7 8 10 11 12 13

Pagina 13

Introduction1-14 MP2100M-LS-2 Modules - Installation and Operation ManualT - Housekeeping ByteS - Framing ByteLEGENDSubstructure No.122038567271706968

Pagina 14

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-15control bit, which indicates the information carried by each byte:0 Control d

Pagina 15

Introduction1-16 MP2100M-LS-2 Modules - Installation and Operation ManualTable 1-5. /SDM Version, Channel Availability for Highest User Rate of9.6 kb

Pagina 16

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-17Module GroupsTo allow the utilization of the maximal number of channels that

Pagina 17

Introduction1-18 MP2100M-LS-2 Modules - Installation and Operation Manual1.3 Technical SpecificationsModule Characteristics See Table 1-1Time Slots Us

Pagina 18 - 3.2 kbps 20 2.4 kbps

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-19Modem bit rates 2.4, 4.8, 9.6 or 19.2 kbps, synchronousModem clocking DTE1 (t

Pagina 19

Introduction1-20 MP2100M-LS-2 Modules - Installation and Operation Manual

Pagina 20

MP2100M-LS-2 Modules - Installation and Operation Manual 2-1Chapter 2.Module Installation andOperation2.1 GeneralThis chapter provides installation, c

Pagina 21

Module Installation and Operation2-2 MP2100M-LS-2 Modules - Installation and Operation Manual2.2 Preparation for InstallationThe operating mode of th

Pagina 22

Module Installation and OperationMP2100M-LS-2 Modules - Installation and Operation Manual 2-3DCE-DTESELECTORSDCEDCEDTEDTECH5CH4MODEDTEDTEMODEDCEDCEDTE

Pagina 23

MP2100M-LS-2 Modules - Installation and Operation Manual iTable of ContentsChapter 1. Introduction1.1 Functional Description ...

Pagina 24 - 1.3 Technical Specifications

Module Installation and Operation2-4 MP2100M-LS-2 Modules - Installation and Operation ManualSections 1, 2, 3 These sections select the channel transm

Pagina 25

Module Installation and OperationMP2100M-LS-2 Modules - Installation and Operation Manual 2-5CH6-10OFF-ASYNCON-SYNCCH1-5S1CH6-10ONOFFOFFLEN0ONOFF9BITL

Pagina 26

Module Installation and Operation2-6 MP2100M-LS-2 Modules - Installation and Operation Manual2.3 Module InstallationFor your safety, do not connect ca

Pagina 27 - Operation

Module Installation and OperationMP2100M-LS-2 Modules - Installation and Operation Manual 2-72.4 Module PanelsThe panels of the LS-2 modules are shown

Pagina 28

Module Installation and Operation2-8 MP2100M-LS-2 Modules - Installation and Operation Manualthe first group of channels (1 through 5) of the local mo

Pagina 29 - Figure 2-2. DIP Switch S1

Module Installation and OperationMP2100M-LS-2 Modules - Installation and Operation Manual 2-92.5 Normal IndicationsThe module starts operating as soon

Pagina 30

Module Installation and Operation2-10 MP2100M-LS-2 Modules - Installation and Operation Manual2.6 Configuration InstructionsGeneralThis section provid

Pagina 31 - 123 65478

Module Installation and OperationMP2100M-LS-2 Modules - Installation and Operation Manual 2-11Table 2-4. External Port ParametersParameter Description

Pagina 32 - 2.3 Module Installation

Module Installation and Operation2-12 MP2100M-LS-2 Modules - Installation and Operation Manual

Pagina 33 - 2.4 Module Panels

MP2100M-LS-2 Modules - Installation and Operation Manual 3-1Chapter 3.Alarms & Diagnostics3.1 GeneralThis chapter provides information on the alar

Pagina 34

ii MP2100M-LS-2 Modules - Installation and Operation ManualModules LS-2, LS-2A, LS-2A/2TS, MTLS-2...

Pagina 35 - 2.5 Normal Indications

Alarms & Diagnostics3-2 MP2100M-LS-2 Modules - Installation and Operation ManualTable 3-1. LS-2 Alarm Messages (Cont’d)Code Message Type Interpret

Pagina 36

Alarms & DiagnosticsMP2100M-LS-2 Modules - Installation and Operation Manual 3-33.3 DiagnosticsLoopback TypesThe LS-2 modules have an extensive se

Pagina 37

Alarms & Diagnostics3-4 MP2100M-LS-2 Modules - Installation and Operation ManualLocal Channel LoopbackThe local channel loopback is performed with

Pagina 38

Alarms & DiagnosticsMP2100M-LS-2 Modules - Installation and Operation Manual 3-5MTLS-2I/O MODULESMTLS-2I/O MODULESLocal UnitSystemManagementRemote

Pagina 39 - Alarms & Diagnostics

Alarms & Diagnostics3-6 MP2100M-LS-2 Modules - Installation and Operation ManualExternally InitiatedLocal ModemLoopback - LS-2/MOnlyThe external i

Pagina 40

Alarms & DiagnosticsMP2100M-LS-2 Modules - Installation and Operation Manual 3-7If the local subscriber receives its own signal when the local loo

Pagina 41 - 3.3 Diagnostics

Alarms & Diagnostics3-8 MP2100M-LS-2 Modules - Installation and Operation Manual

Pagina 42

MP2100M-LS-2 Modules - Installation and Operation Manual A-1Appendix A.Connection DataA.1 Interface Modules for MTLS-2/MTLS-2/2TSThe MTLS-2 and MTLS-

Pagina 43

Connection DataA-2 MP2100M-LS-2 Modules - Installation and Operation ManualThe interface modules have two 68-pin connectors, one for channels 1 throug

Pagina 44

Connection DataMP2100M-LS-2 Modules - Installation and Operation Manual A-3Table A-1. IM-S68/2 and IMB-S68/2 Modules, 68-Pin Connector Pin Assignment

Pagina 45

MP2100M-LS-2 Modules - Installation and Operation Manual iiiList of FiguresFigure 1-1. Typical Application for MTLS-2/X.50 Modules ...

Pagina 46

Connection DataA-4 MP2100M-LS-2 Modules - Installation and Operation ManualA.2 LS-2/M Module ConnectorsEach channel of the LS-2/M module has an RJ-11

Pagina 47 - Connection Data

Connection DataMP2100M-LS-2 Modules - Installation and Operation Manual A-5A.3 LS-2, LS-2A, and LS-2A/TS Modules ConnectorsThe LS-2, LS-2A and LS-2A/

Pagina 48

Connection DataA-6 MP2100M-LS-2 Modules - Installation and Operation ManualTable A-3. LS-2, LS-2A and LS-2A/TS Modules, 44-Pin Connector Pin Assignmen

Pagina 49

iv MP2100M-LS-2 Modules - Installation and Operation ManualList of TablesTable 1-1. Main Characteristics of LS-2 Module Versions ...

Pagina 50 - A.2 LS-2/M Module Connectors

MP2100M-LS-2 Modules - Installation and Operation Manual 1-1Chapter 1.Introduction1.1 Functional DescriptionGeneralThis manual describes the technical

Pagina 51

Introduction1-2 MP2100M-LS-2 Modules - Installation and Operation ManualLS-2 ModuleVersionsTable 1-1 lists the main characteristics of the various LS-

Pagina 52

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-3Main FeaturesThis section describes the main features of the modules offered i