GENERAL
Environment
Temperature: 0° to 55°C (32° to 131°F)
Extended temperature range (metal
enclosure only): -20° to 65°C (-4° to
149°F)
Note: The extended temperature range for
Optimux-108 with V.35 interface is
10° to 60°C (14° to 140°F)
Humidity: Up to 90%, non-condensing
Indicators
Front Panel:
PWR
On (green): both power supplies OK
On (red): power supply A fault
On (yellow): power supply B fault
Off: Both power supplies fault or no
power
LOS/AIS – LINK A/B
On (red): Sync/Signal Loss on Link A/B
On (yellow): AIS detected (products
without Ethernet port only)
Off: normal operation
LOS/AIS – CH1 to CH4
On (red): Signal Loss on channel
On (yellow): AIS received on channel
Off: normal operation
Rear Panel:
Sig Link A/B (on the fiber optic module)
On (green): signal exists on Link A/B
Off: no signal on Link A/B
LINK/ACT
On (yellow): link is up
Off: link is down
Blinking: frames are transmitted
100
On (green): 100 Mbps mode
Off: 10 Mbps mode
Physical
Plastic enclosure:
Height: 4.37 cm (1.7 in)
Width: 21.7 cm (8.5 in)
Depth: 17.0 cm (6.7 in)
Weight: 0.5 kg (1.1 lb)
Metal enclosure:
Height: 4.37 cm (1.7 in)
Width: 21.5 cm (8.4 in)
Depth: 15.3 cm (6.0 in)
Weight: 0.7 kg (1.5 lb)
Power
Wide range power supply
• AC: 100 to 240 VAC
• DC: -48 VDC (-40 to -125 VDC)
24 VDC power supply
• 24 VDC (20 to 36 VDC)
Power Consumption
Wide range power supply
• AC: 25 VA max
• DC (-48 VDC): 9W max
24 VDC power supply
• 9W max