RICi-4E1/T1, RICi-8E1/T1 Installation and Operation Manual Chapter 3 Operation
RICi-4E1/T1, RICi-8E1/T1 Ver. 2.0 Default Settings 3-5
Table
3-3. Default RADIUS Settings
Parameter Default Value
Server Sequence Number 1
Server Status Not connected
Server Access Disable
Server IP Address 0.0.0.0
Number of Retries 2
Timeout 2
Authentication Port 1812
Table
3-4. Default Syslog Settings
Parameter Default Value
Device Logging Status Disable
Device UDP Port 514
Facility Local 1
Severity Level Minor
Server Sequence Number 1
Server Access Disable
Server IP Address 0.0.0.0
Server UDP Port 514
Table
3-5. Default E1 Settings
Parameter Default Value
Activation Up
Transmit Clock Source LBT
Receiver Sensitivity -43
Line Code HDB3
Table
3-6. Default T1 Settings
Parameter Default Value
Activation Up
Transmit Clock Source LBT
Frame Type Framed - ESF
Line Mode CSU
Line BuildOut 0 dB