Chapter 7 Fault Management User’s Manual
7-8 Handling Alarms and Traps Optimux-34 Ver. 2.81
Table 7-5. System Alarm Buffer Parameters
Parameter Possible Values / Remarks
Code The code number for the alarm that occurred
1…120
Read-Only
Description The description of the alarm corresponding to the specified code
Read-Only
Location The device where the alarm ocurred
Local
Remote
Read-Only
Slot Slot or link where the alarm occurred (if applicable)
Link A
Link B
Read-Only
Port Indicates the port number this alarm refers to (if applicable)
Link A
Link B
Channels 1-16
MNG-ETH
USER-ETH
V.35
Read-Only
State Indicates the alarm type
Off: Disappearance of an alarm
Event: Occurrence of an event
Major: Appearance of a major problem
Minor: Appearance of a minor problem
Read-Only
Date & Time The date and time the alarm occurred
Date format: yyyy-mm-dd
Time format: hh:mm:ss
Read-Only
Clearing Alarms in the Alarm Buffer
You can clear the alarm history log contained in the Optimux-34 Alarm Buffer.
Selecting this entry will clear all the entries of the Alarm Buffer.
To clear all alarms in the Alarm Buffer:
On the menu bar, click Fault > History Log > Clear.
The History Log is cleared. No user confirmation is provided.