RAD Data comm Optimux-34 Especificaciones Pagina 108

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 118
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 107
Appendix A Pinouts Installation and Operation Manual
A-2 Ethernet MNG and USER Connectors Optimux-34 Ver. 2.81
RJ-45
BNC
Female
Receive
(Green)
Transmit
(Red)
1
2
3
4
5
6
7
8
Shielded
RJ-45
Transmit
(Red BNC)
Receive
(Green BNC)
RX Ring
RX Tip
NC
TX Ring
TX Tip
NC
NC
NC
.
.
.
.
.
.
Figure
A-1. CBL-RJ45/2BNC/E1/X Cable Wiring Diagram
A.2 Ethernet MNG and USER Connectors
The pin assignment of the MNG and USER Ethernet RJ-45 connectors is listed in
Table
A-2
.
Table
A-2. Ethernet Connector Pinouts
Pin
Number
Pin Name Pin Description Direction
1 TXP TX Data Positive Output
2 TXN TX Data Negative Output
3 RXP RX Data Positive Input
4 NC Conncted to GND via 75 ohm
resistor and 1000PF/2KV capacitor
5 NC Conncted to GND via 75 ohm
resistor and 1000PF/2KV capacitor
6 RXN RX Data Negative Input
7 NC Conncted to GND via 75 ohm
resistor and 1000PF/2KV capacitor
8 NC Conncted to GND via 75 ohm
resistor and 1000PF/2KV capacitor