Appendix D Command Language Installation and Operation Manual
D-2 Front Panel Parameters FCD-E1
Table D-1. System Configuration Parameters
Designation Function Values Configuration Guidelines
CLK_MASTER
Selects the master system
timing reference.
INT – Internal oscillator.
ML – Locked to the recovered main link receive
clock
SL – Locked to the recovered sublink receive clock
CH_1, CH_2 – Locked to the external clock
supplied to the corresponding user data channel,
provided the channel timing mode is DTE2
Default: INT
Select ML or SL for connection to carrier lines.
Select one of the data channels for connection to a data
network.
Select INT at one end and ML at the other end for point-
to-point lines.
CLK_FBACK
Selects the alternate
(fallback) system timing
reference, for use in case
the master reference fails.
NONE – No fallback source is used. In this case, the
internal oscillator is automatically selected when
the master reference fails
ML – Locked to the recovered main link receive
clock
SL – Locked to the recovered sublink receive clock
CH_1, CH_2 – Locked to the external clock
supplied to the corresponding user data channel,
provided the channel timing mode is DTE2
Default: NONE
Select a source different from that selected as master.
Select NONE to disable switching to the fallback source. In
this case, the default fallback clock source is the FCD-E1
internal clock oscillator.