Appendix D Supervision Terminal Commands Installation and Operation Manual
D-14 Commands FCD-E1LC Ver. 1.0
TS : 1 2 3 4 5 6 7 8
TYPE : NO NO NO NO NO NO NO NO
Use the spacebar to move between timeslots. For each timeslot, select
between DATA (timeslot assigned to this data channel) and NO (not
assigned) by pressing <F> or <B>.
After completing the first row, press <Enter> to continue to the next row.
Repeat the procedure until all the timeslots (up to timeslot 31) are
configured.
•
You cannot perform mapping if the main link framing mode is
UNFRM
.
•
Make sure to select enough timeslots to support the selected data rate are
defined.
•
The maximum number of timeslots that can be connected is 31, however
when the main link framing mode is
G732S
, it is not allowed to connect to
timeslot 16.
•
If you already selected an inband management timeslot (using the DEF
DNLOAD command), that timeslot type appears as
DEDIC
and cannot be
changed.
6. Pressing <Enter> after the last timeslot ends the command.